MARC details
000 -LEADER |
fixed length control field |
04798nam a22006977a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
180122s20172017 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1078-5884 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.ejvs.2017.06.014 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1078-5884(17)30388-X [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
28754428 |
245 ## - TITLE STATEMENT |
Title |
Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients. |
251 ## - Source |
Source |
European Journal of Vascular & Endovascular Surgery. 54(3):295-302, 2017 Sep |
252 ## - Abbreviated Source |
Abbreviated source |
Eur J Vasc Endovasc Surg. 54(3):295-302, 2017 Sep |
253 ## - Journal Name |
Journal name |
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2017 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2018 |
266 ## - Date added to catalog |
Date added to catalog |
2018-01-22 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: The chimney and periscope grafts technique was shown to be safe in aortic aneurysm disease involving the supra aortic branches, even in an emergency setting using off the shelf devices. Mid-term follow-up results in this high risk population are good, but longer follow-up is mandatory before this technique is used in intermediate-risk patients. |
520 ## - SUMMARY, ETC. |
Abstract |
Copyright (c) 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. |
520 ## - SUMMARY, ETC. |
Abstract |
PURPOSE: Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Forty-one patients (28.05% EuroScore II) with thoraco-abdominal aortic aneurysm (17%), arch aneurysm (39%), descending aneurysm (34%), and aneurysm extending from the arch to the visceral aorta (10%) were included. Fifteen (37%) patients were treated non-electively. Fifty-nine SABs were treated with the CPG technique: one, two, three, and four CPG were employed in 71%, 19%, 5%, and 5% of patients, respectively. The proximal landing was in zone 0 in 49% of patients, zone 1 in 17%, and zone 2 in 34%. Technical success was 95%. Peri-operative complications and neurological events were registered in six (14.6%) patients and there were 5 deaths (12%). At a median follow-up of 21.2 (mean 22, SD 18; range 0-65) months, type I/III endoleaks were registered in three (7%) cases and re-intervention in six (15%) patients. A significant aneurysm sac shrinkage (p<.001) was reported at mean follow-up and no significant aneurysm sac increase (>5 mm). The estimated 2 year survival, freedom from re-intervention, freedom from endoleak, and freedom from branch occlusion were 75%, 77%, 86%, and 96%, respectively. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Aneurysm, Thoracic/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Blood Vessel Prosthesis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Blood Vessel Prosthesis Implantation/is [Instrumentation] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Endovascular Procedures/is [Instrumentation] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Adult |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged, 80 and over |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Aneurysm, Thoracic/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Aneurysm, Thoracic/mo [Mortality] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortography/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Blood Vessel Prosthesis Implantation/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Blood Vessel Prosthesis Implantation/mo [Mortality] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Computed Tomography Angiography |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Disease-Free Survival |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Endovascular Procedures/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Endovascular Procedures/mo [Mortality] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Kaplan-Meier Estimate |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Middle Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Patient Selection |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Postoperative Complications/et [Etiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Design |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Retrospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Assessment |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Time Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Union Memorial Hospital |
656 ## - INDEX TERM--OCCUPATION |
Department |
Vascular Surgery |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Criado, Frank J |
790 ## - Authors |
All authors |
Cayne NS, Criado FJ, Kruger B, Lachat M, Neff TA, Pakeliani D, Pecoraro F, Pfammatter T, Puippe G, Rancic Z, Veith FJ |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.ejvs.2017.06.014">https://dx.doi.org/10.1016/j.ejvs.2017.06.014</a> |
Public note |
https://dx.doi.org/10.1016/j.ejvs.2017.06.014 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |