Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function. (Record no. 3509)

MARC details
000 -LEADER
fixed length control field 04292nam a22006257a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180706s20192019 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1876-7591
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.jcmg.2018.04.010 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S1936-878X(18)30358-9 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 29909110
245 ## - TITLE STATEMENT
Title Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function.
251 ## - Source
Source Jacc: Cardiovascular Imaging. 12(1):25-34, 2019 01.
252 ## - Abbreviated Source
Abbreviated source JACC Cardiovasc Imaging. 12(1):25-34, 2019 01.
253 ## - Journal Name
Journal name JACC. Cardiovascular imaging
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2019
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2019
266 ## - Date added to catalog
Date added to catalog 2018-07-06
269 ## - Original dates
Original fiscal year FY2018
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Expected transthoracic echocardiographic Doppler-derived hemodynamic data for transcatheter aortic valves inform pre-implant decision-making and post-implanted monitoring of longitudinal valve function.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: Tables of expected mean transcatheter aortic valve hemodynamics by valve type and size are essential in evaluating the function of these transcatheter prosthetic valves. Tables of expected EOA by the native annular anatomy may be useful for pre-implantation decision making. Criteria for defining structural valve dysfunction are proposed.
520 ## - SUMMARY, ETC.
Abstract Copyright (c) 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: We collected the Echocardiography Core Lab measured mean gradients and effective orifice area (EOA) from discharge or 30-day echocardiograms from randomized trials; the PARTNER (Placement of Aortic Transcatheter Valves) trials for the balloon-expandable valves and the Medtronic CoreValve US Pivotal trial and Medtronic CoreValve Evolut R United States IDE Clinical Study for the self-expanding valves.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: This study aims to establish parameters for identifying normal function for each of the 3 iterations of balloon-expandable valves and 2 iterations of self-expanding valves.
520 ## - SUMMARY, ETC.
Abstract RESULTS: For all SAPIEN (Edwards Lifesciences, Irvine, California) valve sizes, mean EOA = 1.70 +/- 0.49 cm<sup>2</sup> with mean gradient of 9.36 +/- 4.13 mm Hg. For all SAPIEN XT valve sizes, mean EOA = 1.67 +/- 0.46 cm<sup>2</sup> with mean gradient of 9.52 +/- 3.64 mm Hg. For all SAPIEN 3 valve sizes, the mean EOA = 1.66 +/- 0.38 cm<sup>2</sup> with mean gradient of 11.18 +/- 4.35 mm Hg. For all CoreValve valve sizes, the mean EOA = 1.88 +/- 0.56 cm<sup>2</sup> with mean gradient of 8.85 +/- 4.14 mm Hg. For all Evolut R valve sizes, the mean EOA = 2.01 +/- 0.65 cm<sup>2</sup> with mean gradient of 7.52 +/- 3.19 mm Hg. The SAPIEN 3 post-implant EOA was progressively larger for each quintile of baseline annular area by computed tomography (p < 0.001). Similarly, for the Evolut R valve, post-implantation EOA was significantly larger for each quintile of baseline annular perimeter (p < 0.001).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve Stenosis/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Aortic Valve/su [Surgery]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Bioprosthesis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Echocardiography, Doppler
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Heart Valve Prosthesis
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Hemodynamics
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Transcatheter Aortic Valve Replacement/is [Instrumentation]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve Stenosis/pp [Physiopathology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Aortic Valve/pp [Physiopathology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Balloon Valvuloplasty
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Multidetector Computed Tomography
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Predictive Value of Tests
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prosthesis Design
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Randomized Controlled Trials as Topic
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Recovery of Function
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Registries
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Time Factors
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Weissman, Neil J
790 ## - Authors
All authors Blanke P, Douglas PS, Hahn RT, Jaber WA, Leipsic J, Oh JK, Pibarot P, Weissman NJ
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.jcmg.2018.04.010">https://dx.doi.org/10.1016/j.jcmg.2018.04.010</a>
Public note https://dx.doi.org/10.1016/j.jcmg.2018.04.010
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 07/06/2018   29909110 29909110 07/06/2018 07/06/2018 Journal Article

Powered by Koha