MARC details
000 -LEADER |
fixed length control field |
04832nam a22006617a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190314s20192019 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1526-6028 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1177/1526602818806653 [doi] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
30681021 |
245 ## - TITLE STATEMENT |
Title |
Stent Placement Across the Renal Vein Inflow in Patients Undergoing Venous Reconstruction Preserves Renal Function and Renal Vein Patency: Experience in 93 Patients. |
251 ## - Source |
Source |
Journal of Endovascular Therapy. 26(2):258-264, 2019 04. |
252 ## - Abbreviated Source |
Abbreviated source |
J Endovasc Ther. 26(2):258-264, 2019 04. |
252 ## - Abbreviated Source |
Former abbreviated source |
J Endovasc Ther. :1526602818806653, 2019 Jan 25 |
253 ## - Journal Name |
Journal name |
Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2019 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2019 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2019-03-14 |
268 ## - Previous citation |
-- |
Journal of Endovascular Therapy. :1526602818806653, 2019 Jan 25 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: Stent placement across the renal vein inflow did not compromise renal function. A very small risk of renal vein thrombosis was seen. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Between June 2008 and September 2016, 93 patients (mean age 39 years, range 15-70; 54 women) with iliocaval occlusion underwent venous stent placement and were retrospectively reviewed. For this analysis, the patients were separated into treatment and control groups: 51 (55%) patients had suprarenal and infrarenal iliocaval venous disease requiring inferior vena cava stent reconstruction across the renal vein inflow (treatment group) and 42 (45%) patients had iliac vein stenting sparing the renal veins (control group). Treatment group patients received Wallstents (n=15), Gianturco Z-stents (n=24), or suprarenal and infrarenal Wallstents such that the renal veins were bracketed with a "renal gap" (n=12). Stenting technical success, stent type, glomerular filtration rate (GFR), and creatinine before and after stent placement were recorded, along with renal vein patency and complications. |
520 ## - SUMMARY, ETC. |
Abstract |
PURPOSE: To determine if stent placement across the renal vein inflow affects kidney function and renal vein patency. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: All procedures were technically successful. In the 51-patient treatment group, 15 (29%) patients received Wallstents and 24 (47%) received Gianturco Z-stents across the renal veins, while 12 (24%) were given a "renal gap" with no stent placement directly across the renal vein inflow. In the control group, 42 patients received iliac vein Wallstents only. Mean prestent GFR was 59+/-1.8 mL/min/1.73 m<sup>2</sup> and mean prestent creatinine was 0.8+/-0.2 mg/dL for the entire cohort. Mean prestent GFR and creatinine values in the Wallstent, Gianturco Z-stent, and "renal gap" subgroups did not differ from the iliac vein stent group. Mean poststent GFR and creatinine values were 59+/-3.3 mL/min/1.73 m<sup>2</sup> and 0.8+/-0.3 mg/dL, respectively. There were no differences between mean pre- and poststent GFR (p=0.32) or creatinine (p=0.41) values when considering all patients or when comparing the treatment subgroups and the control group. There were no differences in the poststent mean GFR or creatinine values between the Wallstent (p=0.21 and p=0.34, respectively) and Gianturco Z-stent (p=0.43 and p=0.41, respectively) groups and the "renal gap" group. One (1%) patient with a Wallstent across the renal veins developed right renal vein thrombosis 7 days after the procedure. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Angioplasty, Balloon/is [Instrumentation] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Renal Veins/pp [Physiopathology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Stents |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Vascular Diseases/th [Therapy] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Vascular Patency |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Adolescent |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Adult |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Angioplasty, Balloon/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Biomarkers/bl [Blood] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Creatinine/bl [Blood] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Glomerular Filtration Rate |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Middle Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Renal Veins/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Retrospective Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Vascular Diseases/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Vascular Diseases/pp [Physiopathology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Venous Thrombosis/et [Etiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Young Adult |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Washington Hospital Center |
656 ## - INDEX TERM--OCCUPATION |
Department |
Surgery/Vascular Surgery |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Abramowitz, Steven D |
790 ## - Authors |
All authors |
Abramowitz SD, Brewerton C, Bundy JJ, Chick JFB, Coleman DM, Fenlon JB, Gemmete JJ, Hage AN, Srinivasa RN, Williams DM |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1177/1526602818806653">https://dx.doi.org/10.1177/1526602818806653</a> |
Public note |
https://dx.doi.org/10.1177/1526602818806653 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |