245 ## - TITLE STATEMENT |
Title |
Lung Ultrasound for Pleural Line Abnormalities, Confluent B-Lines, and Consolidation: Expert Reproducibility and a Method of Standardization. |
251 ## - Source |
Source |
Journal of Ultrasound in Medicine. 2021 Nov 29 |
252 ## - Abbreviated Source |
Abbreviated source |
J Ultrasound Med. 2021 Nov 29 |
253 ## - Journal Name |
Journal name |
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2021 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2021 Nov 29 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2022-01-25 |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: With proposed definitions or via collaboration, overall agreement on confluent B-lines and pleural line to consolidation abnormalities was robust. Pleural line abnormality agreement itself was persistently weak and caution should be used interpreting pleural line abnormalities with only a phased array probe. Copyright (c) 2021 American Institute of Ultrasound in Medicine. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Two raters collaborated to refine definitions, analyzing disagreements on 107 derivation scans from 10 patients. Refined definitions were used by those raters and an independent rater on 1260 validation scans from 105 patients. Reliability was evaluated using intraclass correlation coefficients (ICC) or Cohen's kappa. |
520 ## - SUMMARY, ETC. |
Abstract |
OBJECTIVES: Discrete B-lines have clear definitions, but confluent B-lines, consolidations, and pleural line abnormalities are less well defined. We proposed definitions for these and determined their reproducibility using COVID-19 patient images obtained with phased array probes. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: The agreement was excellent between collaborating raters for B-line abnormalities, ICC = 0.97 (95% confidence interval [CI] 0.97-0.98) and pleural line to consolidation abnormalities, ICC = 0.90 (95% CI 0.87-0.92). The independent rater's agreement for B-line abnormalities was excellent, ICC = 0.97 (95% CI 0.96-0.97) and for pleural line to consolidation was good, ICC = 0.88 (95% CI 0.84-0.91). Agreement just on pleural line abnormalities was weak (collaborators, kappa = 0.54, 95% CI 0.48-0.60; independent, kappa = 0.54, 95% CI 0.49-0.59). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Washington Hospital Center |
656 ## - INDEX TERM--OCCUPATION |
Department |
Medicine/Internal Medicine |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Yasukawa, Kosuke |
790 ## - Authors |
All authors |
Fischer EA, Ma IWY, Minami T, Yasukawa K |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1002/jum.15894">https://dx.doi.org/10.1002/jum.15894</a> |
Public note |
https://dx.doi.org/10.1002/jum.15894 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |